Updated dRAID HOWTO (markdown)
parent
403d49de85
commit
991a475916
|
@ -286,7 +286,13 @@ Again, full redundancy has been restored without adding any new drive. If anothe
|
|||
|
||||
The sequential rebuild process also works for the mirror vdev. Currently it's enabled by default, if a drive is attached to a mirror or a mirror child vdev is replaced, the rebuild process will be called instead of resilver.
|
||||
|
||||
Later it will be changed to use resilver by default, and rebuild only if the user explicitly requests so.
|
||||
Later it will be changed to use resilver by default, and rebuild only if the user explicitly requests so.
|
||||
|
||||
### Rebuild throttling
|
||||
|
||||
The rebuild process may delay _zio_ according to the ZFS options _zfs_scan_idle_ and _zfs_resilver_delay_, which are the same options used by resilver. Moreover, when a dRAID vdev has lost all redundancy, e.g. a draid2 with 2 faulted child drives, the rebuild process will go faster by reducing the delay to _zfs_resilver_delay/2_ because the vdev is now in critical state.
|
||||
|
||||
After delaying, the rebuild zio is issued using priority _ZIO_PRIORITY_SCRUB_ for reads and _ZIO_PRIORITY_ASYNC_WRITE_ for writes. Therefore the options that control the queuing of these two IO priorities will affect rebuild _zio_ as well, for example _zfs_vdev_scrub_min_active_, _zfs_vdev_scrub_max_active_, _zfs_vdev_async_write_min_active_, and _zfs_vdev_async_write_max_active_.
|
||||
|
||||