#!/bin/sh # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License Version 1.0 (CDDL-1.0). # You can obtain a copy of the license from the top-level file # "OPENSOLARIS.LICENSE" or at . # You may not use this file except in compliance with the license. # # CDDL HEADER END # # # Send notification in response to a fault induced statechange # # ZEVENT_SUBCLASS: 'statechange' # ZEVENT_VDEV_STATE_STR: 'DEGRADED', 'FAULTED', 'REMOVED', or 'UNAVAIL' # # Exit codes: # 0: notification sent # 1: notification failed # 2: notification not configured # 3: statechange not relevant # 4: statechange string missing (unexpected) [ -f "${ZED_ZEDLET_DIR}/zed.rc" ] && . "${ZED_ZEDLET_DIR}/zed.rc" . "${ZED_ZEDLET_DIR}/zed-functions.sh" [ -n "${ZEVENT_VDEV_STATE_STR}" ] || exit 4 if [ "${ZEVENT_VDEV_STATE_STR}" != "FAULTED" ] \ && [ "${ZEVENT_VDEV_STATE_STR}" != "DEGRADED" ] \ && [ "${ZEVENT_VDEV_STATE_STR}" != "REMOVED" ] \ && [ "${ZEVENT_VDEV_STATE_STR}" != "UNAVAIL" ]; then exit 3 fi umask 077 note_subject="ZFS device fault for pool ${ZEVENT_POOL} on $(hostname)" note_pathname="$(mktemp)" { if [ "${ZEVENT_VDEV_STATE_STR}" = "FAULTED" ] ; then echo "The number of I/O errors associated with a ZFS device exceeded" echo "acceptable levels. ZFS has marked the device as faulted." elif [ "${ZEVENT_VDEV_STATE_STR}" = "DEGRADED" ] ; then echo "The number of checksum errors associated with a ZFS device" echo "exceeded acceptable levels. ZFS has marked the device as" echo "degraded." else echo "ZFS has detected that a device was removed." fi echo echo " impact: Fault tolerance of the pool may be compromised." echo " eid: ${ZEVENT_EID}" echo " class: ${ZEVENT_SUBCLASS}" echo " state: ${ZEVENT_VDEV_STATE_STR}" echo " host: $(hostname)" echo " time: ${ZEVENT_TIME_STRING}" [ -n "${ZEVENT_VDEV_TYPE}" ] && echo " vtype: ${ZEVENT_VDEV_TYPE}" [ -n "${ZEVENT_VDEV_PATH}" ] && echo " vpath: ${ZEVENT_VDEV_PATH}" [ -n "${ZEVENT_VDEV_PHYSPATH}" ] && echo " vphys: ${ZEVENT_VDEV_PHYSPATH}" [ -n "${ZEVENT_VDEV_GUID}" ] && echo " vguid: ${ZEVENT_VDEV_GUID}" [ -n "${ZEVENT_VDEV_DEVID}" ] && echo " devid: ${ZEVENT_VDEV_DEVID}" echo " pool: ${ZEVENT_POOL} (${ZEVENT_POOL_GUID})" } > "${note_pathname}" zed_notify "${note_subject}" "${note_pathname}"; rv=$? rm -f "${note_pathname}" exit "${rv}"