This patch adds a new top-level vdev type called dRAID, which stands
for Distributed parity RAID. This pool configuration allows all dRAID
vdevs to participate when rebuilding to a distributed hot spare device.
This can substantially reduce the total time required to restore full
parity to pool with a failed device.
A dRAID pool can be created using the new top-level `draid` type.
Like `raidz`, the desired redundancy is specified after the type:
`draid[1,2,3]`. No additional information is required to create the
pool and reasonable default values will be chosen based on the number
of child vdevs in the dRAID vdev.
zpool create <pool> draid[1,2,3] <vdevs...>
Unlike raidz, additional optional dRAID configuration values can be
provided as part of the draid type as colon separated values. This
allows administrators to fully specify a layout for either performance
or capacity reasons. The supported options include:
zpool create <pool> \
draid[<parity>][:<data>d][:<children>c][:<spares>s] \
<vdevs...>
- draid[parity] - Parity level (default 1)
- draid[:<data>d] - Data devices per group (default 8)
- draid[:<children>c] - Expected number of child vdevs
- draid[:<spares>s] - Distributed hot spares (default 0)
Abbreviated example `zpool status` output for a 68 disk dRAID pool
with two distributed spares using special allocation classes.
```
pool: tank
state: ONLINE
config:
NAME STATE READ WRITE CKSUM
slag7 ONLINE 0 0 0
draid2:8d:68c:2s-0 ONLINE 0 0 0
L0 ONLINE 0 0 0
L1 ONLINE 0 0 0
...
U25 ONLINE 0 0 0
U26 ONLINE 0 0 0
spare-53 ONLINE 0 0 0
U27 ONLINE 0 0 0
draid2-0-0 ONLINE 0 0 0
U28 ONLINE 0 0 0
U29 ONLINE 0 0 0
...
U42 ONLINE 0 0 0
U43 ONLINE 0 0 0
special
mirror-1 ONLINE 0 0 0
L5 ONLINE 0 0 0
U5 ONLINE 0 0 0
mirror-2 ONLINE 0 0 0
L6 ONLINE 0 0 0
U6 ONLINE 0 0 0
spares
draid2-0-0 INUSE currently in use
draid2-0-1 AVAIL
```
When adding test coverage for the new dRAID vdev type the following
options were added to the ztest command. These options are leverages
by zloop.sh to test a wide range of dRAID configurations.
-K draid|raidz|random - kind of RAID to test
-D <value> - dRAID data drives per group
-S <value> - dRAID distributed hot spares
-R <value> - RAID parity (raidz or dRAID)
The zpool_create, zpool_import, redundancy, replacement and fault
test groups have all been updated provide test coverage for the
dRAID feature.
Co-authored-by: Isaac Huang <he.huang@intel.com>
Co-authored-by: Mark Maybee <mmaybee@cray.com>
Co-authored-by: Don Brady <don.brady@delphix.com>
Co-authored-by: Matthew Ahrens <mahrens@delphix.com>
Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Mark Maybee <mmaybee@cray.com>
Reviewed-by: Matt Ahrens <matt@delphix.com>
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov>
Closes#10102
The recommended practice for `.Os` on FreeBSD is to not specify any
arguments. The correct OS name is used automatically.
Oddly enough, on the Linux distro I tested this on (CentOS 7), the man
pager defaulted to displaying "BSD" as the OS rather than "Linux". To
accommodate this, tack " Linux" back on in an install hook on Linux.
This is much simpler than removing it for FreeBSD when vendored in the
base system.
Reviewed-by: George Melikov <mail@gmelikov.ru>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ryan Moeller <ryan@iXsystems.com>
Closes#10760
This commit makes the L2ARC persistent across reboots. We implement
a light-weight persistent L2ARC metadata structure that allows L2ARC
contents to be recovered after a reboot. This significantly eases the
impact a reboot has on read performance on systems with large caches.
Reviewed-by: Matthew Ahrens <mahrens@delphix.com>
Reviewed-by: George Wilson <gwilson@delphix.com>
Reviewed-by: Ryan Moeller <ryan@iXsystems.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Co-authored-by: Saso Kiselkov <skiselkov@gmail.com>
Co-authored-by: Jorgen Lundman <lundman@lundman.net>
Co-authored-by: George Amanakis <gamanakis@gmail.com>
Ported-by: Yuxuan Shui <yshuiv7@gmail.com>
Signed-off-by: George Amanakis <gamanakis@gmail.com>
Closes#925Closes#1823Closes#2672Closes#3744Closes#9582
Moved subcommand topics into individual manpages. Reordered and
grouped the list of subcommands by topic.
Moved concepts overview to `zpoolconcepts.8` and the long list of
available pool properties to `zpoolprops.8`.
Internal cross-references copied from `zpool.8` needed to be
converted to `.Xr` external references to new subcommand manual
pages.
Move `autotrim` into lexical order, autotrim tacked onto the end
of a list. Now it is in alphabetical order.
Clarify attach/detach description. Description was too specific to
command syntax. Overview clarifies reason for attaching or detaching
a device.
Clarify replace description, don't refer to subcommand arguments.
Clarify split command description, say what split actually does and
why you'd want to do it.
Clarify description of upgrade, and simplify the zpool.8 wording of
the zpool-upgrade(8) description.
Clarify description of import, detail what zpool-import(8) actually
does.
Add appropriate SEE ALSO sections. Divided zpool subcommand manual
pages need their own SEE ALSO sections. Also modified fsck.zfs.8
to point directly to zfs-scrub.8 and zed.8.in to include a direct
reference to zfs-events.8
Reviewed-by: Matt Ahrens <matt@delphix.com>
Reviewed-by: Kjeld Schouten <kjeld@schouten-lebbing.nl>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ross Williams <ross@ross-williams.net>
Closes#9564