Brian Atkinson 71ce314930 Updating based on PR Feedback(4)
1. When testing out installing a VM with virtual manager on Linux and a
   dataset with direct=always, there an ASSERT failure in
   abd_alloc_from_pages(). Originally zfs_setup_direct() did an
   alignment check of the UIO using SPA_MINBLOCKSIZE with
   zfs_uio_aligned(). The idea behind this was maybe the page alignment
   restriction could be changed to use ashift as the alignment check in
   the future. Howver, this diea never came to be. The alignment
   restrictions for Direct I/O are based on PAGE_SIZE. Updating the
   check zfs_setup_direct() for the UIO to use PAGE_SIZE fixed the
   issue.
2. Updated other alignment check in dmu_read_impl() to also use
   PAGE_SIZE.
3. As a consequence of updating the UIO alignment checks the ZTS test
   case dio_unaligned_filesize began to fail. This is because there was
   no way to detect reading past the end of the file before issue EINVAL
   in the ZPL and VOPs layers in FreeBSD. This was resolved by moving
   zfs_setup_direct() into zfs_write() and zfs_read(). This allows for
   other error checking to take place before checking any Direct I/O
   limitations. Updating the call site of zfs_setup_direct() did require
   a bit of changes to the logic in that function. In particular Direct
   I/O can just be avoid altogether depending on the checks in
   zfs_setup_direct() and there is no reason to return EAGAIN at all.
4. After moving zfs_setup_direct() into zfs_write() and zfs_read(),
   there was no reason to call zfs_check_direct_enabled() in the ZPL
   layer in Linux or in the VNOPS layer of FreeBSD. This function was
   completely removed. This allowed for much of the code in both those
   layers to return to their original code.
5. Upated the checksum verify module parameter for Direct I/O writes to
   only be a boolean and return EIO in the event a checksum verify
   failure occurs. By default, this module parameter is set to 1 for
   Linux and 0 for FreeBSD. The module parameter has been changed to
   zfs_vdev_direct_write_verify. There are still counters on the
   top-level VDEV for checksum verify failures, but this could be
   removed. It would still be good to to leave the ZED event dio_verify
   for checksum failures as a notification that an application was
   manipulating the contents of a buffer after issuing that buffer with
   for I/O using Direct I/O. As part of this cahnge, man pages were
   updated, the ZTS test case dio_writy_verify was updated, and all
   comments relating to the module parameter were udpated as well.
6. Updated comments in dio_property ZTS test to properly reflect that
   stride_dd is being called with check_write and check_read.

Signed-off-by: Brian Atkinson <batkinson@lanl.gov>
2024-09-04 17:08:56 -06:00
Brian Atkinson d93a3febba Adding Direct IO Support
Adding O_DIRECT support to ZFS to bypass the ARC for writes/reads.

O_DIRECT support in ZFS will always ensure there is coherency between
buffered and O_DIRECT IO requests. This ensures that all IO requests,
whether buffered or direct, will see the same file contents at all
times. Just as in other FS's , O_DIRECT does not imply O_SYNC. While
data is written directly to VDEV disks, metadata will not be synced
until the associated  TXG is synced.
For both O_DIRECT read and write request the offset and requeset sizes,
at a minimum, must be PAGE_SIZE aligned. In the event they are not,
then EINVAL is returned unless the direct property is set to always (see
below).

For O_DIRECT writes:
The request also must be block aligned (recordsize) or the write
request will take the normal (buffered) write path. In the event that
request is block aligned and a cached copy of the buffer in the ARC,
then it will be discarded from the ARC forcing all further reads to
retrieve the data from disk.

For O_DIRECT reads:
The only alignment restrictions are PAGE_SIZE alignment. In the event
that the requested data is in buffered (in the ARC) it will just be
copied from the ARC into the user buffer.

For both O_DIRECT writes and reads the O_DIRECT flag will be ignored in
the event that file contents are mmap'ed. In this case, all requests
that are at least PAGE_SIZE aligned will just fall back to the buffered
paths. If the request however is not PAGE_SIZE aligned, EINVAL will
be returned as always regardless if the file's contents are mmap'ed.

Since O_DIRECT writes go through the normal ZIO pipeline, the
following operations are supported just as with normal buffered writes:
Checksum
Compression
Dedup
Encryption
Erasure Coding
There is one caveat for the data integrity of O_DIRECT writes that is
distinct for each of the OS's supported by ZFS.
FreeBSD - FreeBSD is able to place user pages under write protection so
          any data in the user buffers and written directly down to the
	  VDEV disks is guaranteed to not change. There is no concern
	  with data integrity and O_DIRECT writes.
Linux - Linux is not able to place anonymous user pages under write
        protection. Because of this, if the user decides to manipulate
	the page contents while the write operation is occurring, data
	integrity can not be guaranteed. However, there is a module
	parameter `zfs_vdev_direct_write_verify` that contols the
	if a O_DIRECT writes that can occur to a top-level VDEV before
	a checksum verify is run before the contents of the I/O buffer
        are committed to disk. In the event of a checksum verification
	failure the write will return EIO. The number of O_DIRECT write
	checksum verification errors can be observed by doing
	`zpool status -d`, which will list all verification errors that
	have occurred on a top-level VDEV. Along with `zpool status`, a
	ZED event will be issues as `dio_verify` when a checksum
	verification error occurs.

A new dataset property `direct` has been added with the following 3
allowable values:
disabled - Accepts O_DIRECT flag, but silently ignores it and treats
	   the request as a buffered IO request.
standard - Follows the alignment restrictions  outlined above for
	   write/read IO requests when the O_DIRECT flag is used.
always   - Treats every write/read IO request as though it passed
           O_DIRECT and will do O_DIRECT if the alignment restrictions
	   are met otherwise will redirect through the ARC. This
	   property will not allow a request to fail.

There is also a module paramter zfs_dio_enabled that can be used to
force all reads and writes through the ARC. By setting this module
paramter to 0, it mimics as if the  direct dataset property is set to
disabled.

Signed-off-by: Brian Atkinson <batkinson@lanl.gov>
Co-authored-by: Mark Maybee <mark.maybee@delphix.com>
Co-authored-by: Matt Macy <mmacy@FreeBSD.org>
Co-authored-by: Brian Behlendorf <behlendorf@llnl.gov>
2024-09-04 17:06:56 -06:00
Umer Saleem 959e963c81 JSON output support for zpool status
This commit adds support for zpool status command to displpay status
of ZFS pools in JSON format using '-j' option. Status information is
collected in nvlist which is later dumped on stdout in JSON format.
Existing options for zpool status work with '-j' flag. man page for
zpool status is updated accordingly.

Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: Ameer Hamza <ahamza@ixsystems.com>
Signed-off-by: Umer Saleem <usaleem@ixsystems.com>
Closes #16217
2024-08-06 12:47:10 -07:00
Allan Jude 62e7d3c89e
ddt: add support for prefetching tables into the ARC
This change adds a new `zpool prefetch -t ddt $pool` command which
causes a pool's DDT to be loaded into the ARC. The primary goal is to
remove the need to "warm" a pool's cache before deduplication stops
slowing write performance. It may also provide a way to reload portions
of a DDT if they have been flushed due to inactivity.

Sponsored-by: iXsystems, Inc.
Sponsored-by: Catalogics, Inc.
Sponsored-by: Klara, Inc.
Reviewed-by: Alexander Motin <mav@FreeBSD.org>
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Allan Jude <allan@klarasystems.com>
Signed-off-by: Will Andrews <will.andrews@klarasystems.com>
Signed-off-by: Fred Weigel <fred.weigel@klarasystems.com>
Signed-off-by: Rob Norris <rob.norris@klarasystems.com>
Signed-off-by: Don Brady <don.brady@klarasystems.com>
Co-authored-by: Will Andrews <will.andrews@klarasystems.com>
Co-authored-by: Don Brady <don.brady@klarasystems.com>
Closes #15890
2024-07-26 09:16:18 -07:00
Cameron Harr c9d8f6c59a
Fix option string, adding -e and fixing order
The recently added '-e' option (PR #15769) missed adding the
new option in the online `zpool status` help command. This
adds the options and reorders a couple of the other options
that were not listed alphabetically.

Reviewed-by: Brian Atkinson <batkinson@lanl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Cameron Harr <harr1@llnl.gov>
Closes #16008
2024-03-21 09:00:29 -07:00
Cameron Harr 0823388752
Add 'zpool status -e' flag to see unhealthy vdevs
When very large pools are present, it can be laborious to find
reasons for why a pool is degraded and/or where an unhealthy vdev
is. This option filters out vdevs that are ONLINE and with no errors
to make it easier to see where the issues are. Root and parents of
unhealthy vdevs will always be printed.

Testing:
ZFS errors and drive failures for multiple vdevs were simulated with
zinject.

Sample vdev listings with '-e' option
- All vdevs healthy
    NAME        STATE     READ WRITE CKSUM
    iron5       ONLINE       0     0     0

- ZFS errors
    NAME        STATE     READ WRITE CKSUM
    iron5       ONLINE       0     0     0
      raidz2-5  ONLINE       1     0     0
        L23     ONLINE       1     0     0
        L24     ONLINE       1     0     0
        L37     ONLINE       1     0     0

- Vdev faulted
    NAME        STATE     READ WRITE CKSUM
    iron5       DEGRADED     0     0     0
      raidz2-6  DEGRADED     0     0     0
        L67     FAULTED      0     0     0  too many errors

- Vdev faults and data errors
    NAME        STATE     READ WRITE CKSUM
    iron5       DEGRADED     0     0     0
      raidz2-1  DEGRADED     0     0     0
        L2      FAULTED      0     0     0  too many errors
      raidz2-5  ONLINE       1     0     0
        L23     ONLINE       1     0     0
        L24     ONLINE       1     0     0
        L37     ONLINE       1     0     0
      raidz2-6  DEGRADED     0     0     0
        L67     FAULTED      0     0     0  too many errors

- Vdev missing
    NAME        STATE     READ WRITE CKSUM
    iron5       DEGRADED     0     0     0
      raidz2-6  DEGRADED     0     0     0
        L67     UNAVAIL      3     1     0

- Slow devices when -s provided with -e
    NAME        STATE     READ WRITE CKSUM  SLOW
    iron5       DEGRADED     0     0     0     -
      raidz2-5  DEGRADED     0     0     0     -
        L10     FAULTED      0     0     0     0  external device fault
        L51     ONLINE       0     0     0    14

Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Cameron Harr <harr1@llnl.gov>
Closes #15769
2024-02-07 09:12:12 -08:00
Chris Davidson c3fd7a5217
Update man pages to time(1) from time(2)
zpool-iostat.8: Updated time(2) -> time(1) to align to manual page
zpool-list.8: Updated time(2) -> time(1) to align to manual page
zpool-status.8: Updated time(2) -> time(1) to align to manual page
zpool-wait.8: Update time(2) -> time(1) to align to manual page

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Christopher Davidson <christopher.davidson@gmail.com>
Closes #15823
2024-01-29 09:44:08 -08:00
Tony Hutter a9520e6e59
zpool: Add slot power control, print power status
Add `zpool` flags to control the slot power to drives.  This assumes
your SAS or NVMe enclosure supports slot power control via sysfs.

The new `--power` flag is added to `zpool offline|online|clear`:

    zpool offline --power <pool> <device>    Turn off device slot power
    zpool online --power <pool> <device>     Turn on device slot power
    zpool clear --power <pool> [device]      Turn on device slot power

If the ZPOOL_AUTO_POWER_ON_SLOT env var is set, then the '--power'
option is automatically implied for `zpool online` and `zpool clear`
and does not need to be passed.

zpool status also gets a --power option to print the slot power status.

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Mart Frauenlob <AllKind@fastest.cc>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #15662
2023-12-21 10:53:16 -08:00
George Amanakis 6839ec6f10
Enable the head_errlog feature to remove errors
In case check_filesystem() does not error out and does not report
an error, remove that error block from error lists and logs
without requiring a scrub. This can happen when the original file and
all snapshots/clones referencing it have been removed.

Otherwise zpool status will still report that "Permanent errors have
been detected..." without actually reporting any of them.

To implement this change the functions introduced in corrective
receive were modified to take into account the head_errlog feature.

Before this change:
=============================
pool: test
 state: ONLINE
status: One or more devices has experienced an error resulting in data
        corruption.  Applications may be affected.
action: Restore the file in question if possible.  Otherwise restore the
        entire pool from backup.
   see: https://openzfs.github.io/openzfs-docs/msg/ZFS-8000-8A
config:

        NAME                   STATE     READ WRITE CKSUM
        test                   ONLINE       0     0     0
          /home/user/vdev_a    ONLINE       0     0     2

errors: Permanent errors have been detected in the following files:

=============================

After this change:
=============================
  pool: test
 state: ONLINE
status: One or more devices has experienced an unrecoverable error.  An
        attempt was made to correct the error.  Applications are
unaffected.
action: Determine if the device needs to be replaced, and clear the
errors
        using 'zpool clear' or replace the device with 'zpool replace'.
   see: https://openzfs.github.io/openzfs-docs/msg/ZFS-8000-9P
config:

        NAME                   STATE     READ WRITE CKSUM
        test                   ONLINE       0     0     0
          /home/user/vdev_a    ONLINE       0     0     2

errors: No known data errors
=============================

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Brian Atkinson <batkinson@lanl.gov>
Signed-off-by: George Amanakis <gamanakis@gmail.com>
Closes #14813
2023-05-09 08:53:27 -07:00
szubersk b46be903fb Ubuntu 22.04 integration: mancheck
Correct new mandoc errors.
```
STYLE: input text line longer than 80 bytes
STYLE: no blank before trailing delimiter
```

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Richard Yao <richard.yao@alumni.stonybrook.edu>
Reviewed-by: George Melikov <mail@gmelikov.ru>
Signed-off-by: szubersk <szuberskidamian@gmail.com>
Closes #14148
2022-11-18 11:26:41 -08:00
Tino Reichardt 1d3ba0bf01
Replace dead opensolaris.org license link
The commit replaces all findings of the link:
http://www.opensolaris.org/os/licensing with this one:
https://opensource.org/licenses/CDDL-1.0

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tino Reichardt <milky-zfs@mcmilk.de>
Closes #13619
2022-07-11 14:16:13 -07:00
наб 69b06a77b6 man: zpool-iostat.8: import examples from zpool.8
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ahelenia Ziemiańska <nabijaczleweli@nabijaczleweli.xyz>
Closes #13228
2022-03-28 10:13:13 -07:00
наб a737b415d6 man: IO -> I/O; I/Os -> I/O operations again
Reviewed by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ahelenia Ziemiańska <nabijaczleweli@nabijaczleweli.xyz>
Closes #13116
2022-02-22 10:55:37 -08:00
наб 6bf6f5196b man: final VDEV -> vdev
Reviewed by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ahelenia Ziemiańska <nabijaczleweli@nabijaczleweli.xyz>
Closes #13116
2022-02-22 10:55:18 -08:00
наб 2badb3457a Move properties, parameters, events, and concepts around manual sections
The pages moved as follows:
  zpool-features.{5 => 7}
  spl{-module-parameters.5 => .4}
  zfs{-module-parameters.5 => .4}
  zfs-events.5 => into zpool-events.8
  zfsconcepts.{8 => 7}
  zfsprops.{8 => 7}
  zpoolconcepts.{8 => 7}
  zpoolprops.{8 => 7}

Reviewed-by: Richard Laager <rlaager@wiktel.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ahelenia Ziemiańska <nabijaczleweli@nabijaczleweli.xyz>
Co-authored-by: Daniel Ebdrup Jensen <debdrup@FreeBSD.org>
Closes #12149
Closes #12212
2021-06-09 14:35:30 -07:00
наб f84fe3fc87 Lint most manpages
Reviewed-by: Richard Laager <rlaager@wiktel.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Tony Nguyen <tony.nguyen@delphix.com>
Reviewed-by: Ryan Moeller <ryan@iXsystems.com>
Signed-off-by: Ahelenia Ziemiańska <nabijaczleweli@nabijaczleweli.xyz>
Closes #12129
2021-06-04 12:48:31 -07:00
xtouqh 1e36af8c7b
Properly format NAME subsection of zfs/zpool subcommands
Use proper names (i.e. zfs-allow and zpool-add) in NAME subsections
of zfs/zpool subcommands instead of current "pretty-printed" ones as
makewhatis utilities (or some implementations of it, namely the one
from mandoc suite used in FreeBSD) look not only at the document title
but also in NAME subsection, adding zfs(8)/zpool(8) to search results
which is not correct. (Common sense and other utilities splitting
subcommands in multiple man pages, e.g. git, do the same.)

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: xtouqh <xtouqh@hotmail.com>
Closes #11086
2020-10-22 11:28:10 -07:00
Ryan Moeller 6706552ea6
Remove hard coded "Linux" OS from manpages
The recommended practice for `.Os` on FreeBSD is to not specify any
arguments.  The correct OS name is used automatically.

Oddly enough, on the Linux distro I tested this on (CentOS 7), the man
pager defaulted to displaying "BSD" as the OS rather than "Linux".  To
accommodate this, tack " Linux" back on in an install hook on Linux.
This is much simpler than removing it for FreeBSD when vendored in the
base system.

Reviewed-by: George Melikov <mail@gmelikov.ru>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ryan Moeller <ryan@iXsystems.com>
Closes #10760
2020-08-21 11:55:47 -07:00
Brian Behlendorf 9a49d3f3d3
Add device rebuild feature
The device_rebuild feature enables sequential reconstruction when
resilvering.  Mirror vdevs can be rebuilt in LBA order which may
more quickly restore redundancy depending on the pools average block
size, overall fragmentation and the performance characteristics
of the devices.  However, block checksums cannot be verified
as part of the rebuild thus a scrub is automatically started after
the sequential resilver completes.

The new '-s' option has been added to the `zpool attach` and
`zpool replace` command to request sequential reconstruction
instead of healing reconstruction when resilvering.

    zpool attach -s <pool> <existing vdev> <new vdev>
    zpool replace -s <pool> <old vdev> <new vdev>

The `zpool status` output has been updated to report the progress
of sequential resilvering in the same way as healing resilvering.
The one notable difference is that multiple sequential resilvers
may be in progress as long as they're operating on different
top-level vdevs.

The `zpool wait -t resilver` command was extended to wait on
sequential resilvers.  From this perspective they are no different
than healing resilvers.

Sequential resilvers cannot be supported for RAIDZ, but are
compatible with the dRAID feature being developed.

As part of this change the resilver_restart_* tests were moved
in to the functional/replacement directory.  Additionally, the
replacement tests were renamed and extended to verify both
resilvering and rebuilding.

Original-patch-by: Isaac Huang <he.huang@intel.com>
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: John Poduska <jpoduska@datto.com>
Co-authored-by: Mark Maybee <mmaybee@cray.com>
Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov>
Closes #10349
2020-07-03 11:05:50 -07:00
Ross Williams c5ebfbbe19 Reorganize zpool(8) man page into sections
Moved subcommand topics into individual manpages. Reordered and 
grouped the list of subcommands by topic.

Moved concepts overview to `zpoolconcepts.8` and the long list of
available pool properties to `zpoolprops.8`.

Internal cross-references copied from `zpool.8` needed to be 
converted to `.Xr` external references to new subcommand manual 
pages.

Move `autotrim` into lexical order, autotrim tacked onto the end
of a list. Now it is in alphabetical order.

Clarify attach/detach description. Description was too specific to
command syntax. Overview clarifies reason for attaching or detaching
a device.

Clarify replace description, don't refer to subcommand arguments.

Clarify split command description, say what split actually does and
why you'd want to do it.

Clarify description of upgrade, and simplify the zpool.8 wording of
the zpool-upgrade(8) description.

Clarify description of import, detail what zpool-import(8) actually 
does.

Add appropriate SEE ALSO sections. Divided zpool subcommand manual 
pages need their own SEE ALSO sections. Also modified fsck.zfs.8 
to point directly to zfs-scrub.8 and zed.8.in to include a direct
reference to zfs-events.8

Reviewed-by: Matt Ahrens <matt@delphix.com>
Reviewed-by: Kjeld Schouten <kjeld@schouten-lebbing.nl>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ross Williams <ross@ross-williams.net>
Closes #9564
2019-11-13 09:21:07 -08:00