Commit Graph

3 Commits

Author SHA1 Message Date
Ryan Moeller 6706552ea6
Remove hard coded "Linux" OS from manpages
The recommended practice for `.Os` on FreeBSD is to not specify any
arguments.  The correct OS name is used automatically.

Oddly enough, on the Linux distro I tested this on (CentOS 7), the man
pager defaulted to displaying "BSD" as the OS rather than "Linux".  To
accommodate this, tack " Linux" back on in an install hook on Linux.
This is much simpler than removing it for FreeBSD when vendored in the
base system.

Reviewed-by: George Melikov <mail@gmelikov.ru>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ryan Moeller <ryan@iXsystems.com>
Closes #10760
2020-08-21 11:55:47 -07:00
Brian Behlendorf 2288d41968
Add trim support to zpool wait
Manual trims fall into the category of long-running pool activities
which people might want to wait synchronously for. This change adds
support to 'zpool wait' for waiting for manual trim operations to
complete. It also adds a '-w' flag to 'zpool trim' which can be used to
turn 'zpool trim' into a synchronous operation.

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Serapheim Dimitropoulos <serapheim@delphix.com>
Signed-off-by: John Gallagher <john.gallagher@delphix.com>
Closes #10071
2020-03-04 15:07:11 -08:00
Ross Williams c5ebfbbe19 Reorganize zpool(8) man page into sections
Moved subcommand topics into individual manpages. Reordered and 
grouped the list of subcommands by topic.

Moved concepts overview to `zpoolconcepts.8` and the long list of
available pool properties to `zpoolprops.8`.

Internal cross-references copied from `zpool.8` needed to be 
converted to `.Xr` external references to new subcommand manual 
pages.

Move `autotrim` into lexical order, autotrim tacked onto the end
of a list. Now it is in alphabetical order.

Clarify attach/detach description. Description was too specific to
command syntax. Overview clarifies reason for attaching or detaching
a device.

Clarify replace description, don't refer to subcommand arguments.

Clarify split command description, say what split actually does and
why you'd want to do it.

Clarify description of upgrade, and simplify the zpool.8 wording of
the zpool-upgrade(8) description.

Clarify description of import, detail what zpool-import(8) actually 
does.

Add appropriate SEE ALSO sections. Divided zpool subcommand manual 
pages need their own SEE ALSO sections. Also modified fsck.zfs.8 
to point directly to zfs-scrub.8 and zed.8.in to include a direct
reference to zfs-events.8

Reviewed-by: Matt Ahrens <matt@delphix.com>
Reviewed-by: Kjeld Schouten <kjeld@schouten-lebbing.nl>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ross Williams <ross@ross-williams.net>
Closes #9564
2019-11-13 09:21:07 -08:00