The recently added '-e' option (PR #15769) missed adding the
new option in the online `zpool status` help command. This
adds the options and reorders a couple of the other options
that were not listed alphabetically.
Reviewed-by: Brian Atkinson <batkinson@lanl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Cameron Harr <harr1@llnl.gov>
Closes#16008
When very large pools are present, it can be laborious to find
reasons for why a pool is degraded and/or where an unhealthy vdev
is. This option filters out vdevs that are ONLINE and with no errors
to make it easier to see where the issues are. Root and parents of
unhealthy vdevs will always be printed.
Testing:
ZFS errors and drive failures for multiple vdevs were simulated with
zinject.
Sample vdev listings with '-e' option
- All vdevs healthy
NAME STATE READ WRITE CKSUM
iron5 ONLINE 0 0 0
- ZFS errors
NAME STATE READ WRITE CKSUM
iron5 ONLINE 0 0 0
raidz2-5 ONLINE 1 0 0
L23 ONLINE 1 0 0
L24 ONLINE 1 0 0
L37 ONLINE 1 0 0
- Vdev faulted
NAME STATE READ WRITE CKSUM
iron5 DEGRADED 0 0 0
raidz2-6 DEGRADED 0 0 0
L67 FAULTED 0 0 0 too many errors
- Vdev faults and data errors
NAME STATE READ WRITE CKSUM
iron5 DEGRADED 0 0 0
raidz2-1 DEGRADED 0 0 0
L2 FAULTED 0 0 0 too many errors
raidz2-5 ONLINE 1 0 0
L23 ONLINE 1 0 0
L24 ONLINE 1 0 0
L37 ONLINE 1 0 0
raidz2-6 DEGRADED 0 0 0
L67 FAULTED 0 0 0 too many errors
- Vdev missing
NAME STATE READ WRITE CKSUM
iron5 DEGRADED 0 0 0
raidz2-6 DEGRADED 0 0 0
L67 UNAVAIL 3 1 0
- Slow devices when -s provided with -e
NAME STATE READ WRITE CKSUM SLOW
iron5 DEGRADED 0 0 0 -
raidz2-5 DEGRADED 0 0 0 -
L10 FAULTED 0 0 0 0 external device fault
L51 ONLINE 0 0 0 14
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Cameron Harr <harr1@llnl.gov>
Closes#15769
zpool-iostat.8: Updated time(2) -> time(1) to align to manual page
zpool-list.8: Updated time(2) -> time(1) to align to manual page
zpool-status.8: Updated time(2) -> time(1) to align to manual page
zpool-wait.8: Update time(2) -> time(1) to align to manual page
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Christopher Davidson <christopher.davidson@gmail.com>
Closes#15823
Add `zpool` flags to control the slot power to drives. This assumes
your SAS or NVMe enclosure supports slot power control via sysfs.
The new `--power` flag is added to `zpool offline|online|clear`:
zpool offline --power <pool> <device> Turn off device slot power
zpool online --power <pool> <device> Turn on device slot power
zpool clear --power <pool> [device] Turn on device slot power
If the ZPOOL_AUTO_POWER_ON_SLOT env var is set, then the '--power'
option is automatically implied for `zpool online` and `zpool clear`
and does not need to be passed.
zpool status also gets a --power option to print the slot power status.
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Mart Frauenlob <AllKind@fastest.cc>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes#15662
In case check_filesystem() does not error out and does not report
an error, remove that error block from error lists and logs
without requiring a scrub. This can happen when the original file and
all snapshots/clones referencing it have been removed.
Otherwise zpool status will still report that "Permanent errors have
been detected..." without actually reporting any of them.
To implement this change the functions introduced in corrective
receive were modified to take into account the head_errlog feature.
Before this change:
=============================
pool: test
state: ONLINE
status: One or more devices has experienced an error resulting in data
corruption. Applications may be affected.
action: Restore the file in question if possible. Otherwise restore the
entire pool from backup.
see: https://openzfs.github.io/openzfs-docs/msg/ZFS-8000-8A
config:
NAME STATE READ WRITE CKSUM
test ONLINE 0 0 0
/home/user/vdev_a ONLINE 0 0 2
errors: Permanent errors have been detected in the following files:
=============================
After this change:
=============================
pool: test
state: ONLINE
status: One or more devices has experienced an unrecoverable error. An
attempt was made to correct the error. Applications are
unaffected.
action: Determine if the device needs to be replaced, and clear the
errors
using 'zpool clear' or replace the device with 'zpool replace'.
see: https://openzfs.github.io/openzfs-docs/msg/ZFS-8000-9P
config:
NAME STATE READ WRITE CKSUM
test ONLINE 0 0 0
/home/user/vdev_a ONLINE 0 0 2
errors: No known data errors
=============================
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Brian Atkinson <batkinson@lanl.gov>
Signed-off-by: George Amanakis <gamanakis@gmail.com>
Closes#14813
Correct new mandoc errors.
```
STYLE: input text line longer than 80 bytes
STYLE: no blank before trailing delimiter
```
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Richard Yao <richard.yao@alumni.stonybrook.edu>
Reviewed-by: George Melikov <mail@gmelikov.ru>
Signed-off-by: szubersk <szuberskidamian@gmail.com>
Closes#14148
Use proper names (i.e. zfs-allow and zpool-add) in NAME subsections
of zfs/zpool subcommands instead of current "pretty-printed" ones as
makewhatis utilities (or some implementations of it, namely the one
from mandoc suite used in FreeBSD) look not only at the document title
but also in NAME subsection, adding zfs(8)/zpool(8) to search results
which is not correct. (Common sense and other utilities splitting
subcommands in multiple man pages, e.g. git, do the same.)
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: xtouqh <xtouqh@hotmail.com>
Closes#11086
The recommended practice for `.Os` on FreeBSD is to not specify any
arguments. The correct OS name is used automatically.
Oddly enough, on the Linux distro I tested this on (CentOS 7), the man
pager defaulted to displaying "BSD" as the OS rather than "Linux". To
accommodate this, tack " Linux" back on in an install hook on Linux.
This is much simpler than removing it for FreeBSD when vendored in the
base system.
Reviewed-by: George Melikov <mail@gmelikov.ru>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ryan Moeller <ryan@iXsystems.com>
Closes#10760
The device_rebuild feature enables sequential reconstruction when
resilvering. Mirror vdevs can be rebuilt in LBA order which may
more quickly restore redundancy depending on the pools average block
size, overall fragmentation and the performance characteristics
of the devices. However, block checksums cannot be verified
as part of the rebuild thus a scrub is automatically started after
the sequential resilver completes.
The new '-s' option has been added to the `zpool attach` and
`zpool replace` command to request sequential reconstruction
instead of healing reconstruction when resilvering.
zpool attach -s <pool> <existing vdev> <new vdev>
zpool replace -s <pool> <old vdev> <new vdev>
The `zpool status` output has been updated to report the progress
of sequential resilvering in the same way as healing resilvering.
The one notable difference is that multiple sequential resilvers
may be in progress as long as they're operating on different
top-level vdevs.
The `zpool wait -t resilver` command was extended to wait on
sequential resilvers. From this perspective they are no different
than healing resilvers.
Sequential resilvers cannot be supported for RAIDZ, but are
compatible with the dRAID feature being developed.
As part of this change the resilver_restart_* tests were moved
in to the functional/replacement directory. Additionally, the
replacement tests were renamed and extended to verify both
resilvering and rebuilding.
Original-patch-by: Isaac Huang <he.huang@intel.com>
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Reviewed-by: John Poduska <jpoduska@datto.com>
Co-authored-by: Mark Maybee <mmaybee@cray.com>
Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov>
Closes#10349
Moved subcommand topics into individual manpages. Reordered and
grouped the list of subcommands by topic.
Moved concepts overview to `zpoolconcepts.8` and the long list of
available pool properties to `zpoolprops.8`.
Internal cross-references copied from `zpool.8` needed to be
converted to `.Xr` external references to new subcommand manual
pages.
Move `autotrim` into lexical order, autotrim tacked onto the end
of a list. Now it is in alphabetical order.
Clarify attach/detach description. Description was too specific to
command syntax. Overview clarifies reason for attaching or detaching
a device.
Clarify replace description, don't refer to subcommand arguments.
Clarify split command description, say what split actually does and
why you'd want to do it.
Clarify description of upgrade, and simplify the zpool.8 wording of
the zpool-upgrade(8) description.
Clarify description of import, detail what zpool-import(8) actually
does.
Add appropriate SEE ALSO sections. Divided zpool subcommand manual
pages need their own SEE ALSO sections. Also modified fsck.zfs.8
to point directly to zfs-scrub.8 and zed.8.in to include a direct
reference to zfs-events.8
Reviewed-by: Matt Ahrens <matt@delphix.com>
Reviewed-by: Kjeld Schouten <kjeld@schouten-lebbing.nl>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Ross Williams <ross@ross-williams.net>
Closes#9564