Tony Hutter 54c6fbd378 zed: Allow autoreplace and fault LEDs for removed vdevs
Allow zed to autoreplace vdevs marked as REMOVED.  Also update
statechange-led zedlet to toggle fault LEDs for REMOVED vdevs.

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #15281
2023-09-19 08:52:06 -07:00
Damian Szuberski c1d3be19d7
Add ShellCheck's `--enable=all` inside `cmd/`
The only exception is `cmd/vdev_id/vdev_id` which might be a subject of
refactoring (see #12084)

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Ahelenia Ziemiańska <nabijaczleweli@nabijaczleweli.xyz>
Signed-off-by: szubersk <szuberskidamian@gmail.com>
Closes #12912
2022-01-06 16:07:54 -08:00
Tony Hutter ae70d628ff
zed: Control NVMe fault LEDs
The ZED code currently can only turn on the fault LED for
a faulted disk in a JBOD enclosure.  This extends support
for faulted NVMe disks as well.

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #12648
Closes #12695
2021-11-09 16:50:18 -08:00
наб 71def603cd zed.d/pool_import-led.sh: fix for current zpool scripts
Also minor clean-up with folding state_to_val() into a case,
unrolling the lesser-available seq into numbers,
ignoring vdev states we don't care about,
and documentation comments

Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Signed-off-by: Ahelenia Ziemiańska <nabijaczleweli@nabijaczleweli.xyz>
Closes #11934
Closes #11935
2021-04-30 15:04:28 -07:00
Andrea Gelmini ad0b23b14a Fix typos in cmd/
Reviewed-by: Ryan Moeller <ryan@ixsystems.com>
Reviewed-by: Richard Laager <rlaager@wiktel.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Andrea Gelmini <andrea.gelmini@gelma.net>
Closes #9234
2019-08-30 09:43:30 -07:00
bunder2015 bf6ca0a631 shellcheck pass
note: which is non-standard. Use builtin 'command -v' instead. [SC2230]
note: Use -n instead of ! -z. [SC2236]

Reviewed-by: George Melikov <mail@gmelikov.ru>
Reviewed-by: Giuseppe Di Natale <guss80@gmail.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: bunder2015 <omfgbunder@gmail.com>
Closes #8367
2019-02-04 09:07:19 -08:00
Giuseppe Di Natale c552fbc5f0 Enable shellcheck to run for select scripts
Enable shellcheck to run on zed scripts,
paxcheck.sh, zfs-tests.sh, zfs.sh, and zloop.sh.

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Signed-off-by: Giuseppe Di Natale <dinatale2@llnl.gov>
Closes #5812
2017-03-09 10:20:15 -08:00
Christopher Voltz 100790a8dd Retry setting LED
If the LED is being accessed by another process when we try to update
it, the update will be lost. Add a retry loop which will read the state
of the LED and update it until the LED is in the correct state. The
number of times this will occur is limited to ensure that the ZEDlet
won't hang ZED.

Refactor to remove duplication so setting of the LED occurs in only one
place.

Cleanup a couple of the warnings generated by shellcheck which weren't
the result of specific choices by the author. Several notes and warnings
are still present but removing them would make the code less clear or
require adding lines to tell shellcheck to ignore the warning.

Remove ",i" from the documentation at the top of the file which appears
to be a typographic error.

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Reviewed-by: Tony Hutter <hutter2@llnl.gov>
Signed-off-by: Christopher Voltz <christopher.voltz@hpe.com>
Closes #5795
2017-02-16 13:41:48 -08:00
Tony Hutter b291029e86 Enclosure LED fixes
- Pass $VDEV_ENC_SYSFS_PATH to 'zpool [iostat|status] -c' to include
  enclosure LED sysfs path.

- Set LEDs correctly after import.  This includes clearing any erroniously
  set LEDs prior to the import, and setting the LED for any UNAVAIL drives.

- Include symlink for vdev_attach-led.sh in Makefile.am.

- Print the VDEV path in all-syslog.sh, and fix it so the pool GUID actually
  prints.    

Reviewed-by: Don Brady <don.brady@intel.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #5716 
Closes #5751
2017-02-10 16:09:45 -08:00
Tony Hutter 8720e9e748 Add -c to zpool iostat & status to run command
This patch adds a command (-c) option to zpool status and zpool iostat.  The
-c option allows you to run an arbitrary command on each vdev and display
the first line of output in zpool status/iostat.  The environment vars
VDEV_PATH and VDEV_UPATH are set to the vdev's path and "underlying path"
before running the command.  For device mapper, multipath, or partitioned
vdevs, VDEV_UPATH is the actual underlying /dev/sd* disk.  This can be useful
if the command you're running requires a /dev/sd* device.

The patch also uses /sys/block/<dev>/slaves/ to lookup the underlying device
instead of using libdevmapper.  This not only removes the libdevmapper
requirement at build time, but also allows you to resolve device mapper
devices without being root.  This means that UDEV_UPATH get set correctly
when running zpool status/iostat as an unprivileged user.

Example:

$ zpool status -c 'echo I am $VDEV_PATH, $VDEV_UPATH'

NAME        STATE     READ WRITE CKSUM
mypool      ONLINE       0     0     0
  mirror-0  ONLINE       0     0     0
    mpatha  ONLINE       0     0     0  I am /dev/mapper/mpatha, /dev/sdc
    sdb     ONLINE       0     0     0  I am /dev/sdb1, /dev/sdb

Reviewed-by: Giuseppe Di Natale <dinatale2@llnl.gov>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #5368
2016-11-29 14:45:38 -07:00
Tony Hutter 6568379eea Fix statechange-led.sh & unnecessary libdevmapper warning
- Fix autoreplace behaviour on statechange-led.sh script.

ZED sends the following events on an auto-replace:

1. statechange: Disk goes UNAVAIL->ONLINE
2. statechange: Disk goes ONLINE->UNAVAIL
3. vdev_attach: Disk goes ONLINE

Events 1-2 happen when ZED first attempts to do an auto-online.  When that
fails, ZED then tries an auto-replace, generating the vdev_attach event in #3.

In the previous code, statechange-led was only looking at the UNAVAIL->ONLINE
transition to turn off the LED.  It ignored the #2 ONLINE->UNAVAIL transition,
assuming it was just the "old" VDEV going offline.  This is problematic, as
a drive can go from ONLINE->UNAVAIL when it's malfunctioning, and we don't want
to ignore that.

This new patch correctly turns on the fault LED every time a drive becomes
UNAVAIL.  It also monitors vdev_attach events to trigger turning off the LED
when an auto-replaced disk comes online.

- Remove unnecessary libdevmapper warning with --with-config=kernel

This fixes an unnecessary libdevmapper warning when building
--with-config=kernel.  Kernel code does not use libdevmapper, so the warning
is not needed.

Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #2375 
Closes #5312 
Closes #5331
2016-10-25 11:05:30 -07:00
Tony Hutter 1bbd877049 Turn on/off enclosure slot fault LED even when disk isn't present
Previously when a drive faulted, the statechange-led.sh script would lookup
the drive's LED sysfs entry in /sys/block/sd*/device/enclosure_device, and
turn it on.  During testing we noticed that if you pulled out a drive, or if
the drive was so badly broken that it no longer appeared to Linux, that the
/sys/block/sd* path would be removed, and the script could not lookup the
LED entry.

To fix this, this patch looks up the disks's more persistent
"/sys/class/enclosure/X:X:X:X/Slot N" LED sysfs path at pool import.  It then
passes that path to the statechange-led script to use, rather than having the
script look it up on the fly.  This allows the script to turn on/off the slot
LEDs even when the drive is missing.

Closes #5309 
Closes #2375
2016-10-24 10:45:59 -07:00
Tony Hutter 6078881aa1 Multipath autoreplace, control enclosure LEDs, event rate limiting
1. Enable multipath autoreplace support for FMA.

This extends FMA autoreplace to work with multipath disks.  This
requires libdevmapper to be installed at build time.

2. Turn on/off fault LEDs when VDEVs become degraded/faulted/online

Set ZED_USE_ENCLOSURE_LEDS=1 in zed.rc to have ZED turn on/off the enclosure
LED for a drive when a drive becomes FAULTED/DEGRADED.  Your enclosure must
be supported by the Linux SES driver for this to work.  The enclosure LED
scripts work for multipath devices as well.  The scripts will clear the LED
when the fault is cleared.

3. Rate limit ZIO delay and checksum events so as not to flood ZED

ZIO delay and checksum events are rate limited to 5/sec in the zfs module.

Reviewed-by: Richard Laager <rlaager@wiktel.com>
Reviewed by: Don Brady <don.brady@intel.com>
Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov>
Signed-off-by: Tony Hutter <hutter2@llnl.gov>
Closes #2449 
Closes #3017 
Closes #5159
2016-10-19 12:55:59 -07:00