zfs/tests/zfs-tests/cmd/draid.c

1405 lines
33 KiB
C
Raw Normal View History

Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
/*
* CDDL HEADER START
*
* The contents of this file are subject to the terms of the
* Common Development and Distribution License (the "License").
* You may not use this file except in compliance with the License.
*
* You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
* or https://opensource.org/licenses/CDDL-1.0.
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
* See the License for the specific language governing permissions
* and limitations under the License.
*
* When distributing Covered Code, include this CDDL HEADER in each
* file and include the License file at usr/src/OPENSOLARIS.LICENSE.
* If applicable, add the following below this CDDL HEADER, with the
* fields enclosed by brackets "[]" replaced with your own identifying
* information: Portions Copyright [yyyy] [name of copyright owner]
*
* CDDL HEADER END
*/
/*
* Copyright (c) 2018 Intel Corporation.
* Copyright (c) 2020 by Lawrence Livermore National Security, LLC.
*/
#include <stdio.h>
#include <zlib.h>
#include <zfs_fletcher.h>
#include <sys/vdev_draid.h>
#include <sys/nvpair.h>
#include <sys/stat.h>
/*
* The number of rows to generate for new permutation maps.
*/
#define MAP_ROWS_DEFAULT 256
/*
* Key values for dRAID maps when stored as nvlists.
*/
#define MAP_SEED "seed"
#define MAP_CHECKSUM "checksum"
#define MAP_WORST_RATIO "worst_ratio"
#define MAP_AVG_RATIO "avg_ratio"
#define MAP_CHILDREN "children"
#define MAP_NPERMS "nperms"
#define MAP_PERMS "perms"
static void
draid_usage(void)
{
(void) fprintf(stderr,
"usage: draid command args ...\n"
"Available commands are:\n"
"\n"
"\tdraid generate [-cv] [-m min] [-n max] [-p passes] FILE\n"
"\tdraid verify [-rv] FILE\n"
"\tdraid dump [-v] [-m min] [-n max] FILE\n"
"\tdraid table FILE\n"
"\tdraid merge FILE SRC SRC...\n");
exit(1);
}
static int
read_map(const char *filename, nvlist_t **allcfgs)
{
int block_size = 131072;
int buf_size = 131072;
int tmp_size, error;
char *tmp_buf;
struct stat64 stat;
if (lstat64(filename, &stat) != 0)
return (errno);
if (stat.st_size == 0 ||
!(S_ISREG(stat.st_mode) || S_ISLNK(stat.st_mode))) {
return (EINVAL);
}
gzFile fp = gzopen(filename, "rb");
if (fp == Z_NULL)
return (errno);
char *buf = malloc(buf_size);
if (buf == NULL) {
(void) gzclose(fp);
return (ENOMEM);
}
ssize_t rc, bytes = 0;
while (!gzeof(fp)) {
rc = gzread(fp, buf + bytes, block_size);
if ((rc < 0) || (rc == 0 && !gzeof(fp))) {
free(buf);
(void) gzclose(fp);
(void) gzerror(fp, &error);
return (error);
} else {
bytes += rc;
if (bytes + block_size >= buf_size) {
tmp_size = 2 * buf_size;
tmp_buf = malloc(tmp_size);
if (tmp_buf == NULL) {
free(buf);
(void) gzclose(fp);
return (ENOMEM);
}
memcpy(tmp_buf, buf, bytes);
free(buf);
buf = tmp_buf;
buf_size = tmp_size;
}
}
}
(void) gzclose(fp);
error = nvlist_unpack(buf, bytes, allcfgs, 0);
free(buf);
return (error);
}
/*
* Read a map from the specified filename. A file contains multiple maps
* which are indexed by the number of children. The caller is responsible
* for freeing the configuration returned.
*/
static int
read_map_key(const char *filename, const char *key, nvlist_t **cfg)
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
{
nvlist_t *allcfgs, *foundcfg = NULL;
int error;
error = read_map(filename, &allcfgs);
if (error != 0)
return (error);
Fix unchecked return values and unused return values Coverity complained about unchecked return values and unused values that turned out to be unused return values. Different approaches were used to handle the different cases of unchecked return values: * cmd/zdb/zdb.c: VERIFY0 was used in one place since the existing code had no error handling. An error message was printed in another to match the rest of the code. * cmd/zed/agents/zfs_retire.c: We dismiss the return value with `(void)` because the value is expected to be potentially unset. * cmd/zpool_influxdb/zpool_influxdb.c: We dismiss the return value with `(void)` because the values are expected to be potentially unset. * cmd/ztest.c: VERIFY0 was used since we want failures if something goes wrong in ztest. * module/zfs/dsl_dir.c: We dismiss the return value with `(void)` because there is no guarantee that the zap entry will always be there. For example, old pools imported readonly would not have it and we do not want to fail here because of that. * module/zfs/zfs_fm.c: `fnvlist_add_*()` was used since the allocations sleep and thus can never fail. * module/zfs/zvol.c: We dismiss the return value with `(void)` because we do not need it. This matches what is already done in the analogous `zfs_replay_write2()`. * tests/zfs-tests/cmd/draid.c: We suppress one return value with `(void)` since the code handles errors already. The other return value is handled by switching to `fnvlist_lookup_uint8_array()`. * tests/zfs-tests/cmd/file/file_fadvise.c: We add error handling. * tests/zfs-tests/cmd/mmap_sync.c: We add error handling for munmap, but ignore failures on remove() with (void) since it is expected to be able to fail. * tests/zfs-tests/cmd/mmapwrite.c: We add error handling. As for unused return values, they were all in places where there was error handling, so logic was added to handle the return values. Reviewed-by: Alexander Motin <mav@FreeBSD.org> Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov> Signed-off-by: Richard Yao <richard.yao@alumni.stonybrook.edu> Closes #13920
2022-09-23 23:52:03 +00:00
(void) nvlist_lookup_nvlist(allcfgs, key, &foundcfg);
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
if (foundcfg != NULL) {
nvlist_dup(foundcfg, cfg, KM_SLEEP);
error = 0;
} else {
error = ENOENT;
}
nvlist_free(allcfgs);
return (error);
}
/*
* Write all mappings to the map file.
*/
static int
write_map(const char *filename, nvlist_t *allcfgs)
{
size_t buflen = 0;
int error;
error = nvlist_size(allcfgs, &buflen, NV_ENCODE_XDR);
if (error)
return (error);
char *buf = malloc(buflen);
if (buf == NULL)
return (ENOMEM);
error = nvlist_pack(allcfgs, &buf, &buflen, NV_ENCODE_XDR, KM_SLEEP);
if (error) {
free(buf);
return (error);
}
/*
* Atomically update the file using a temporary file and the
* traditional unlink then rename steps. This code provides
* no locking, it only guarantees the packed nvlist on disk
* is updated atomically and is internally consistent.
*/
char *tmpname = calloc(1, MAXPATHLEN);
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
if (tmpname == NULL) {
free(buf);
return (ENOMEM);
}
snprintf(tmpname, MAXPATHLEN - 1, "%s.XXXXXX", filename);
int fd = mkstemp(tmpname);
if (fd < 0) {
error = errno;
free(buf);
free(tmpname);
return (error);
}
(void) close(fd);
gzFile fp = gzopen(tmpname, "w9b");
if (fp == Z_NULL) {
error = errno;
free(buf);
free(tmpname);
return (errno);
}
ssize_t rc, bytes = 0;
while (bytes < buflen) {
size_t size = MIN(buflen - bytes, 131072);
rc = gzwrite(fp, buf + bytes, size);
if (rc < 0) {
free(buf);
(void) gzerror(fp, &error);
(void) gzclose(fp);
(void) unlink(tmpname);
free(tmpname);
return (error);
} else if (rc == 0) {
break;
} else {
bytes += rc;
}
}
free(buf);
(void) gzclose(fp);
if (bytes != buflen) {
(void) unlink(tmpname);
free(tmpname);
return (EIO);
}
/*
* Unlink the previous config file and replace it with the updated
* version. If we're able to unlink the file then directory is
* writable by us and the subsequent rename should never fail.
*/
error = unlink(filename);
if (error != 0 && errno != ENOENT) {
error = errno;
(void) unlink(tmpname);
free(tmpname);
return (error);
}
error = rename(tmpname, filename);
if (error != 0) {
error = errno;
(void) unlink(tmpname);
free(tmpname);
return (error);
}
free(tmpname);
return (0);
}
/*
* Add the dRAID map to the file and write it out.
*/
static int
write_map_key(const char *filename, char *key, draid_map_t *map,
double worst_ratio, double avg_ratio)
{
nvlist_t *nv_cfg, *allcfgs;
int error;
/*
* Add the configuration to an existing or new file. The new
* configuration will replace an existing configuration with the
* same key if it has a lower ratio and is therefore better.
*/
error = read_map(filename, &allcfgs);
if (error == ENOENT) {
allcfgs = fnvlist_alloc();
} else if (error != 0) {
return (error);
}
error = nvlist_lookup_nvlist(allcfgs, key, &nv_cfg);
if (error == 0) {
uint64_t nv_cfg_worst_ratio = fnvlist_lookup_uint64(nv_cfg,
MAP_WORST_RATIO);
double nv_worst_ratio = (double)nv_cfg_worst_ratio / 1000.0;
if (worst_ratio < nv_worst_ratio) {
/* Replace old map with the more balanced new map. */
fnvlist_remove(allcfgs, key);
} else {
/* The old map is preferable, keep it. */
nvlist_free(allcfgs);
return (EEXIST);
}
}
nvlist_t *cfg = fnvlist_alloc();
fnvlist_add_uint64(cfg, MAP_SEED, map->dm_seed);
fnvlist_add_uint64(cfg, MAP_CHECKSUM, map->dm_checksum);
fnvlist_add_uint64(cfg, MAP_CHILDREN, map->dm_children);
fnvlist_add_uint64(cfg, MAP_NPERMS, map->dm_nperms);
fnvlist_add_uint8_array(cfg, MAP_PERMS, map->dm_perms,
map->dm_children * map->dm_nperms * sizeof (uint8_t));
fnvlist_add_uint64(cfg, MAP_WORST_RATIO,
(uint64_t)(worst_ratio * 1000.0));
fnvlist_add_uint64(cfg, MAP_AVG_RATIO,
(uint64_t)(avg_ratio * 1000.0));
error = nvlist_add_nvlist(allcfgs, key, cfg);
if (error == 0)
error = write_map(filename, allcfgs);
nvlist_free(cfg);
nvlist_free(allcfgs);
return (error);
}
static void
dump_map(draid_map_t *map, const char *key, double worst_ratio,
double avg_ratio, int verbose)
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
{
if (verbose == 0) {
return;
} else if (verbose == 1) {
printf(" \"%s\": seed: 0x%016llx worst_ratio: %2.03f "
"avg_ratio: %2.03f\n", key, (u_longlong_t)map->dm_seed,
worst_ratio, avg_ratio);
return;
} else {
printf(" \"%s\":\n"
" seed: 0x%016llx\n"
" checksum: 0x%016llx\n"
" worst_ratio: %2.03f\n"
" avg_ratio: %2.03f\n"
" children: %llu\n"
" nperms: %llu\n",
key, (u_longlong_t)map->dm_seed,
(u_longlong_t)map->dm_checksum, worst_ratio, avg_ratio,
(u_longlong_t)map->dm_children,
(u_longlong_t)map->dm_nperms);
if (verbose > 2) {
printf(" perms = {\n");
for (int i = 0; i < map->dm_nperms; i++) {
printf(" { ");
for (int j = 0; j < map->dm_children; j++) {
printf("%3d%s ", map->dm_perms[
i * map->dm_children + j],
j < map->dm_children - 1 ?
"," : "");
}
printf(" },\n");
}
printf(" }\n");
} else if (verbose == 2) {
printf(" draid_perms = <omitted>\n");
}
}
}
static void
dump_map_nv(const char *key, nvlist_t *cfg, int verbose)
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
{
draid_map_t map;
uint_t c;
uint64_t worst_ratio = fnvlist_lookup_uint64(cfg, MAP_WORST_RATIO);
uint64_t avg_ratio = fnvlist_lookup_uint64(cfg, MAP_AVG_RATIO);
map.dm_seed = fnvlist_lookup_uint64(cfg, MAP_SEED);
map.dm_checksum = fnvlist_lookup_uint64(cfg, MAP_CHECKSUM);
map.dm_children = fnvlist_lookup_uint64(cfg, MAP_CHILDREN);
map.dm_nperms = fnvlist_lookup_uint64(cfg, MAP_NPERMS);
Fix unchecked return values and unused return values Coverity complained about unchecked return values and unused values that turned out to be unused return values. Different approaches were used to handle the different cases of unchecked return values: * cmd/zdb/zdb.c: VERIFY0 was used in one place since the existing code had no error handling. An error message was printed in another to match the rest of the code. * cmd/zed/agents/zfs_retire.c: We dismiss the return value with `(void)` because the value is expected to be potentially unset. * cmd/zpool_influxdb/zpool_influxdb.c: We dismiss the return value with `(void)` because the values are expected to be potentially unset. * cmd/ztest.c: VERIFY0 was used since we want failures if something goes wrong in ztest. * module/zfs/dsl_dir.c: We dismiss the return value with `(void)` because there is no guarantee that the zap entry will always be there. For example, old pools imported readonly would not have it and we do not want to fail here because of that. * module/zfs/zfs_fm.c: `fnvlist_add_*()` was used since the allocations sleep and thus can never fail. * module/zfs/zvol.c: We dismiss the return value with `(void)` because we do not need it. This matches what is already done in the analogous `zfs_replay_write2()`. * tests/zfs-tests/cmd/draid.c: We suppress one return value with `(void)` since the code handles errors already. The other return value is handled by switching to `fnvlist_lookup_uint8_array()`. * tests/zfs-tests/cmd/file/file_fadvise.c: We add error handling. * tests/zfs-tests/cmd/mmap_sync.c: We add error handling for munmap, but ignore failures on remove() with (void) since it is expected to be able to fail. * tests/zfs-tests/cmd/mmapwrite.c: We add error handling. As for unused return values, they were all in places where there was error handling, so logic was added to handle the return values. Reviewed-by: Alexander Motin <mav@FreeBSD.org> Reviewed-by: Brian Behlendorf <behlendorf1@llnl.gov> Signed-off-by: Richard Yao <richard.yao@alumni.stonybrook.edu> Closes #13920
2022-09-23 23:52:03 +00:00
map.dm_perms = fnvlist_lookup_uint8_array(cfg, MAP_PERMS, &c);
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
dump_map(&map, key, (double)worst_ratio / 1000.0,
avg_ratio / 1000.0, verbose);
}
/*
* Print a summary of the mapping.
*/
static int
dump_map_key(const char *filename, const char *key, int verbose)
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
{
nvlist_t *cfg;
int error;
error = read_map_key(filename, key, &cfg);
if (error != 0)
return (error);
dump_map_nv(key, cfg, verbose);
return (0);
}
/*
* Allocate a new permutation map for evaluation.
*/
static int
alloc_new_map(uint64_t children, uint64_t nperms, uint64_t seed,
draid_map_t **mapp)
{
draid_map_t *map;
int error;
map = malloc(sizeof (draid_map_t));
if (map == NULL)
return (ENOMEM);
map->dm_children = children;
map->dm_nperms = nperms;
map->dm_seed = seed;
map->dm_checksum = 0;
error = vdev_draid_generate_perms(map, &map->dm_perms);
if (error) {
free(map);
return (error);
}
*mapp = map;
return (0);
}
/*
* Allocate the fixed permutation map for N children.
*/
static int
alloc_fixed_map(uint64_t children, draid_map_t **mapp)
{
const draid_map_t *fixed_map;
draid_map_t *map;
int error;
error = vdev_draid_lookup_map(children, &fixed_map);
if (error)
return (error);
map = malloc(sizeof (draid_map_t));
if (map == NULL)
return (ENOMEM);
memcpy(map, fixed_map, sizeof (draid_map_t));
VERIFY3U(map->dm_checksum, !=, 0);
error = vdev_draid_generate_perms(map, &map->dm_perms);
if (error) {
free(map);
return (error);
}
*mapp = map;
return (0);
}
/*
* Free a permutation map.
*/
static void
free_map(draid_map_t *map)
{
free(map->dm_perms);
free(map);
}
/*
* Check if dev is in the provided list of faulted devices.
*/
static inline boolean_t
is_faulted(int *faulted_devs, int nfaulted, int dev)
{
for (int i = 0; i < nfaulted; i++)
if (faulted_devs[i] == dev)
return (B_TRUE);
return (B_FALSE);
}
/*
* Evaluate how resilvering I/O will be distributed given a list of faulted
* vdevs. As a simplification we assume one IO is sufficient to repair each
* damaged device in a group.
*/
static double
eval_resilver(draid_map_t *map, uint64_t groupwidth, uint64_t nspares,
int *faulted_devs, int nfaulted, int *min_child_ios, int *max_child_ios)
{
uint64_t children = map->dm_children;
uint64_t ngroups = 1;
uint64_t ndisks = children - nspares;
/*
* Calculate the minimum number of groups required to fill a slice.
*/
while (ngroups * (groupwidth) % (children - nspares) != 0)
ngroups++;
int *ios = calloc(map->dm_children, sizeof (uint64_t));
/* Resilver all rows */
for (int i = 0; i < map->dm_nperms; i++) {
uint8_t *row = &map->dm_perms[i * map->dm_children];
/* Resilver all groups with faulted drives */
for (int j = 0; j < ngroups; j++) {
uint64_t spareidx = map->dm_children - nspares;
boolean_t repair_needed = B_FALSE;
/* See if any devices in this group are faulted */
uint64_t groupstart = (j * groupwidth) % ndisks;
for (int k = 0; k < groupwidth; k++) {
uint64_t groupidx = (groupstart + k) % ndisks;
repair_needed = is_faulted(faulted_devs,
nfaulted, row[groupidx]);
if (repair_needed)
break;
}
if (repair_needed == B_FALSE)
continue;
/*
* This group is degraded. Calculate the number of
* reads the non-faulted drives require and the number
* of writes to the distributed hot spare for this row.
*/
for (int k = 0; k < groupwidth; k++) {
uint64_t groupidx = (groupstart + k) % ndisks;
if (!is_faulted(faulted_devs, nfaulted,
row[groupidx])) {
ios[row[groupidx]]++;
} else if (nspares > 0) {
while (is_faulted(faulted_devs,
nfaulted, row[spareidx])) {
spareidx++;
}
ASSERT3U(spareidx, <, map->dm_children);
ios[row[spareidx]]++;
spareidx++;
}
}
}
}
*min_child_ios = INT_MAX;
*max_child_ios = 0;
/*
* Find the drives with fewest and most required I/O. These values
* are used to calculate the imbalance ratio. To avoid returning an
* infinite value for permutations which have children that perform
* no IO a floor of 1 IO per child is set. This ensures a meaningful
* ratio is returned for comparison and it is not an uncommon when
* there are a large number of children.
*/
for (int i = 0; i < map->dm_children; i++) {
if (is_faulted(faulted_devs, nfaulted, i)) {
ASSERT0(ios[i]);
continue;
}
if (ios[i] == 0)
ios[i] = 1;
if (ios[i] < *min_child_ios)
*min_child_ios = ios[i];
if (ios[i] > *max_child_ios)
*max_child_ios = ios[i];
}
ASSERT3S(*min_child_ios, !=, INT_MAX);
ASSERT3S(*max_child_ios, !=, 0);
double ratio = (double)(*max_child_ios) / (double)(*min_child_ios);
free(ios);
return (ratio);
}
/*
* Evaluate the quality of the permutation mapping by considering possible
* device failures. Returns the imbalance ratio for the worst mapping which
* is defined to be the largest number of child IOs over the fewest number
* child IOs. A value of 1.0 indicates the mapping is perfectly balance and
* all children perform an equal amount of work during reconstruction.
*/
static void
eval_decluster(draid_map_t *map, double *worst_ratiop, double *avg_ratiop)
{
uint64_t children = map->dm_children;
double worst_ratio = 1.0;
double sum = 0;
int worst_min_ios = 0, worst_max_ios = 0;
int n = 0;
/*
* When there are only 2 children there can be no distributed
* spare and no resilver to evaluate. Default to a ratio of 1.0
* for this degenerate case.
*/
if (children == VDEV_DRAID_MIN_CHILDREN) {
*worst_ratiop = 1.0;
*avg_ratiop = 1.0;
return;
}
/*
* Score the mapping as if it had either 1 or 2 distributed spares.
*/
for (int nspares = 1; nspares <= 2; nspares++) {
uint64_t faults = nspares;
/*
* Score groupwidths up to 19. This value was chosen as the
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
* largest reasonable width (16d+3p). dRAID pools may be still
* be created with wider stripes but they are not considered in
* this analysis in order to optimize for the most common cases.
*/
for (uint64_t groupwidth = 2;
groupwidth <= MIN(children - nspares, 19);
groupwidth++) {
int faulted_devs[2];
int min_ios, max_ios;
/*
* Score possible devices faults. This is limited
* to exactly one fault per distributed spare for
* the purposes of this similation.
*/
for (int f1 = 0; f1 < children; f1++) {
faulted_devs[0] = f1;
double ratio;
if (faults == 1) {
ratio = eval_resilver(map, groupwidth,
nspares, faulted_devs, faults,
&min_ios, &max_ios);
if (ratio > worst_ratio) {
worst_ratio = ratio;
worst_min_ios = min_ios;
worst_max_ios = max_ios;
}
sum += ratio;
n++;
} else if (faults == 2) {
for (int f2 = f1 + 1; f2 < children;
f2++) {
faulted_devs[1] = f2;
ratio = eval_resilver(map,
groupwidth, nspares,
faulted_devs, faults,
&min_ios, &max_ios);
if (ratio > worst_ratio) {
worst_ratio = ratio;
worst_min_ios = min_ios;
worst_max_ios = max_ios;
}
sum += ratio;
n++;
}
}
}
}
}
*worst_ratiop = worst_ratio;
*avg_ratiop = sum / n;
/*
* Log the min/max io values for particularly unbalanced maps.
* Since the maps are generated entirely randomly these are possible
* be exceedingly unlikely. We log it for possible investigation.
*/
if (worst_ratio > 100.0) {
dump_map(map, "DEBUG", worst_ratio, *avg_ratiop, 2);
printf("worst_min_ios=%d worst_max_ios=%d\n",
worst_min_ios, worst_max_ios);
}
}
static int
eval_maps(uint64_t children, int passes, uint64_t *map_seed,
draid_map_t **best_mapp, double *best_ratiop, double *avg_ratiop)
{
draid_map_t *best_map = NULL;
double best_worst_ratio = 1000.0;
double best_avg_ratio = 1000.0;
/*
* Perform the requested number of passes evaluating randomly
* generated permutation maps. Only the best version is kept.
*/
for (int i = 0; i < passes; i++) {
double worst_ratio, avg_ratio;
draid_map_t *map;
int error;
/*
* Calculate the next seed and generate a new candidate map.
*/
error = alloc_new_map(children, MAP_ROWS_DEFAULT,
vdev_draid_rand(map_seed), &map);
if (error)
return (error);
/*
* Consider maps with a lower worst_ratio to be of higher
* quality. Some maps may have a lower avg_ratio but they
* are discarded since they might include some particularly
* imbalanced permutations. The average is tracked to in
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
* order to get a sense of the average permutation quality.
*/
eval_decluster(map, &worst_ratio, &avg_ratio);
if (best_map == NULL || worst_ratio < best_worst_ratio) {
if (best_map != NULL)
free_map(best_map);
best_map = map;
best_worst_ratio = worst_ratio;
best_avg_ratio = avg_ratio;
} else {
free_map(map);
}
}
/*
* After determining the best map generate a checksum over the full
* permutation array. This checksum is verified when opening a dRAID
* pool to ensure the generated in memory permutations are correct.
*/
zio_cksum_t cksum;
fletcher_4_native_varsize(best_map->dm_perms,
sizeof (uint8_t) * best_map->dm_children * best_map->dm_nperms,
&cksum);
best_map->dm_checksum = cksum.zc_word[0];
*best_mapp = best_map;
*best_ratiop = best_worst_ratio;
*avg_ratiop = best_avg_ratio;
return (0);
}
static int
draid_generate(int argc, char *argv[])
{
char filename[MAXPATHLEN] = {0};
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
uint64_t map_seed;
int c, fd, error, verbose = 0, passes = 1, continuous = 0;
int min_children = VDEV_DRAID_MIN_CHILDREN;
int max_children = VDEV_DRAID_MAX_CHILDREN;
int restarts = 0;
while ((c = getopt(argc, argv, ":cm:n:p:v")) != -1) {
switch (c) {
case 'c':
continuous++;
break;
case 'm':
min_children = (int)strtol(optarg, NULL, 0);
if (min_children < VDEV_DRAID_MIN_CHILDREN) {
(void) fprintf(stderr, "A minimum of 2 "
"children are required.\n");
return (1);
}
break;
case 'n':
max_children = (int)strtol(optarg, NULL, 0);
if (max_children > VDEV_DRAID_MAX_CHILDREN) {
(void) fprintf(stderr, "A maximum of %d "
"children are allowed.\n",
VDEV_DRAID_MAX_CHILDREN);
return (1);
}
break;
case 'p':
passes = (int)strtol(optarg, NULL, 0);
break;
case 'v':
/*
* 0 - Only log when a better map is added to the file.
* 1 - Log the current best map for each child count.
* Minimal output on a single summary line.
* 2 - Log the current best map for each child count.
* More verbose includes most map fields.
* 3 - Log the current best map for each child count.
* Very verbose all fields including the full map.
*/
verbose++;
break;
case ':':
(void) fprintf(stderr,
"missing argument for '%c' option\n", optopt);
draid_usage();
break;
case '?':
(void) fprintf(stderr, "invalid option '%c'\n",
optopt);
draid_usage();
break;
}
}
if (argc > optind)
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
strncpy(filename, argv[optind], MAXPATHLEN - 1);
else {
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
(void) fprintf(stderr, "A FILE must be specified.\n");
return (1);
}
restart:
/*
* Start with a fresh seed from /dev/urandom.
*/
fd = open("/dev/urandom", O_RDONLY);
if (fd < 0) {
printf("Unable to open /dev/urandom: %s\n:", strerror(errno));
return (1);
} else {
ssize_t bytes = sizeof (map_seed);
ssize_t bytes_read = 0;
while (bytes_read < bytes) {
ssize_t rc = read(fd, ((char *)&map_seed) + bytes_read,
bytes - bytes_read);
if (rc < 0) {
printf("Unable to read /dev/urandom: %s\n:",
strerror(errno));
close(fd);
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
return (1);
}
bytes_read += rc;
}
(void) close(fd);
}
if (restarts == 0)
printf("Writing generated mappings to '%s':\n", filename);
/*
* Generate maps for all requested child counts. The best map for
* each child count is written out to the specified file. If the file
* already contains a better mapping this map will not be added.
*/
for (uint64_t children = min_children;
children <= max_children; children++) {
char key[8] = { 0 };
draid_map_t *map;
double worst_ratio = 1000.0;
double avg_ratio = 1000.0;
error = eval_maps(children, passes, &map_seed, &map,
&worst_ratio, &avg_ratio);
if (error) {
printf("Error eval_maps(): %s\n", strerror(error));
return (1);
}
if (worst_ratio < 1.0 || avg_ratio < 1.0) {
printf("Error ratio < 1.0: worst_ratio = %2.03f "
"avg_ratio = %2.03f\n", worst_ratio, avg_ratio);
return (1);
}
snprintf(key, 7, "%llu", (u_longlong_t)children);
error = write_map_key(filename, key, map, worst_ratio,
avg_ratio);
if (error == 0) {
/* The new map was added to the file. */
dump_map(map, key, worst_ratio, avg_ratio,
MAX(verbose, 1));
} else if (error == EEXIST) {
/* The existing map was preferable and kept. */
if (verbose > 0)
dump_map_key(filename, key, verbose);
} else {
printf("Error write_map_key(): %s\n", strerror(error));
return (1);
}
free_map(map);
}
/*
* When the continuous option is set restart at the minimum number of
* children instead of exiting. This option is useful as a mechanism
* to continuous try and refine the discovered permutations.
*/
if (continuous) {
restarts++;
printf("Restarting by request (-c): %d\n", restarts);
goto restart;
}
return (0);
}
/*
* Verify each map in the file by generating its in-memory permutation array
* and comfirming its checksum is correct.
*/
static int
draid_verify(int argc, char *argv[])
{
char filename[MAXPATHLEN] = {0};
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
int n = 0, c, error, verbose = 1;
int check_ratios = 0;
while ((c = getopt(argc, argv, ":rv")) != -1) {
switch (c) {
case 'r':
check_ratios++;
break;
case 'v':
verbose++;
break;
case ':':
(void) fprintf(stderr,
"missing argument for '%c' option\n", optopt);
draid_usage();
break;
case '?':
(void) fprintf(stderr, "invalid option '%c'\n",
optopt);
draid_usage();
break;
}
}
if (argc > optind) {
char *abspath = malloc(MAXPATHLEN);
if (abspath == NULL)
return (ENOMEM);
if (realpath(argv[optind], abspath) != NULL)
strncpy(filename, abspath, MAXPATHLEN - 1);
else
strncpy(filename, argv[optind], MAXPATHLEN - 1);
free(abspath);
} else {
(void) fprintf(stderr, "A FILE must be specified.\n");
return (1);
}
printf("Verifying permutation maps: '%s'\n", filename);
/*
* Lookup hardcoded permutation map for each valid number of children
* and verify a generated map has the correct checksum. Then compare
* the generated map values with the nvlist map values read from the
* reference file to cross-check the permutation.
*/
for (uint64_t children = VDEV_DRAID_MIN_CHILDREN;
children <= VDEV_DRAID_MAX_CHILDREN;
children++) {
draid_map_t *map;
char key[8] = {0};
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
snprintf(key, 8, "%llu", (u_longlong_t)children);
error = alloc_fixed_map(children, &map);
if (error) {
printf("Error alloc_fixed_map() failed: %s\n",
error == ECKSUM ? "Invalid checksum" :
strerror(error));
return (1);
}
uint64_t nv_seed, nv_checksum, nv_children, nv_nperms;
uint8_t *nv_perms;
nvlist_t *cfg;
uint_t c;
error = read_map_key(filename, key, &cfg);
if (error != 0) {
printf("Error read_map_key() failed: %s\n",
strerror(error));
free_map(map);
return (1);
}
nv_seed = fnvlist_lookup_uint64(cfg, MAP_SEED);
nv_checksum = fnvlist_lookup_uint64(cfg, MAP_CHECKSUM);
nv_children = fnvlist_lookup_uint64(cfg, MAP_CHILDREN);
nv_nperms = fnvlist_lookup_uint64(cfg, MAP_NPERMS);
nvlist_lookup_uint8_array(cfg, MAP_PERMS, &nv_perms, &c);
/*
* Compare draid_map_t and nvlist reference values.
*/
if (map->dm_seed != nv_seed) {
printf("Error different seeds: 0x%016llx != "
"0x%016llx\n", (u_longlong_t)map->dm_seed,
(u_longlong_t)nv_seed);
error = EINVAL;
}
if (map->dm_checksum != nv_checksum) {
printf("Error different checksums: 0x%016llx "
"!= 0x%016llx\n",
(u_longlong_t)map->dm_checksum,
(u_longlong_t)nv_checksum);
error = EINVAL;
}
if (map->dm_children != nv_children) {
printf("Error different children: %llu "
"!= %llu\n", (u_longlong_t)map->dm_children,
(u_longlong_t)nv_children);
error = EINVAL;
}
if (map->dm_nperms != nv_nperms) {
printf("Error different nperms: %llu "
"!= %llu\n", (u_longlong_t)map->dm_nperms,
(u_longlong_t)nv_nperms);
error = EINVAL;
}
for (uint64_t i = 0; i < nv_children * nv_nperms; i++) {
if (map->dm_perms[i] != nv_perms[i]) {
printf("Error different perms[%llu]: "
"%d != %d\n", (u_longlong_t)i,
(int)map->dm_perms[i],
(int)nv_perms[i]);
error = EINVAL;
break;
}
}
/*
* For good measure recalculate the worst and average
* ratios and confirm they match the nvlist values.
*/
if (check_ratios) {
uint64_t nv_worst_ratio, nv_avg_ratio;
double worst_ratio, avg_ratio;
eval_decluster(map, &worst_ratio, &avg_ratio);
nv_worst_ratio = fnvlist_lookup_uint64(cfg,
MAP_WORST_RATIO);
nv_avg_ratio = fnvlist_lookup_uint64(cfg,
MAP_AVG_RATIO);
if (worst_ratio < 1.0 || avg_ratio < 1.0) {
printf("Error ratio out of range %2.03f, "
"%2.03f\n", worst_ratio, avg_ratio);
error = EINVAL;
}
if ((uint64_t)(worst_ratio * 1000.0) !=
nv_worst_ratio) {
printf("Error different worst_ratio %2.03f "
"!= %2.03f\n", (double)nv_worst_ratio /
1000.0, worst_ratio);
error = EINVAL;
}
if ((uint64_t)(avg_ratio * 1000.0) != nv_avg_ratio) {
printf("Error different average_ratio %2.03f "
"!= %2.03f\n", (double)nv_avg_ratio /
1000.0, avg_ratio);
error = EINVAL;
}
}
if (error) {
free_map(map);
nvlist_free(cfg);
return (1);
}
if (verbose > 0) {
printf("- %llu children: good\n",
(u_longlong_t)children);
}
n++;
free_map(map);
nvlist_free(cfg);
}
if (n != (VDEV_DRAID_MAX_CHILDREN - 1)) {
printf("Error permutation maps missing: %d / %d checked\n",
n, VDEV_DRAID_MAX_CHILDREN - 1);
return (1);
}
printf("Successfully verified %d / %d permutation maps\n",
n, VDEV_DRAID_MAX_CHILDREN - 1);
return (0);
}
/*
* Dump the contents of the specified mapping(s) for inspection.
*/
static int
draid_dump(int argc, char *argv[])
{
char filename[MAXPATHLEN] = {0};
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
int c, error, verbose = 1;
int min_children = VDEV_DRAID_MIN_CHILDREN;
int max_children = VDEV_DRAID_MAX_CHILDREN;
while ((c = getopt(argc, argv, ":vm:n:")) != -1) {
switch (c) {
case 'm':
min_children = (int)strtol(optarg, NULL, 0);
if (min_children < 2) {
(void) fprintf(stderr, "A minimum of 2 "
"children are required.\n");
return (1);
}
break;
case 'n':
max_children = (int)strtol(optarg, NULL, 0);
if (max_children > VDEV_DRAID_MAX_CHILDREN) {
(void) fprintf(stderr, "A maximum of %d "
"children are allowed.\n",
VDEV_DRAID_MAX_CHILDREN);
return (1);
}
break;
case 'v':
verbose++;
break;
case ':':
(void) fprintf(stderr,
"missing argument for '%c' option\n", optopt);
draid_usage();
break;
case '?':
(void) fprintf(stderr, "invalid option '%c'\n",
optopt);
draid_usage();
break;
}
}
if (argc > optind)
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
strncpy(filename, argv[optind], MAXPATHLEN - 1);
else {
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
(void) fprintf(stderr, "A FILE must be specified.\n");
return (1);
}
/*
* Dump maps for the requested child counts.
*/
for (uint64_t children = min_children;
children <= max_children; children++) {
char key[8] = { 0 };
snprintf(key, 7, "%llu", (u_longlong_t)children);
error = dump_map_key(filename, key, verbose);
if (error) {
printf("Error dump_map_key(): %s\n", strerror(error));
return (1);
}
}
return (0);
}
/*
* Print all of the mappings as a C formatted draid_map_t array. This table
* is found in the module/zcommon/zfs_draid.c file and is the definitive
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
* source for all mapping used by dRAID. It cannot be updated without
* changing the dRAID on disk format.
*/
static int
draid_table(int argc, char *argv[])
{
char filename[MAXPATHLEN] = {0};
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
int error;
if (argc > optind)
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
strncpy(filename, argv[optind], MAXPATHLEN - 1);
else {
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
(void) fprintf(stderr, "A FILE must be specified.\n");
return (1);
}
printf("static const draid_map_t "
"draid_maps[VDEV_DRAID_MAX_MAPS] = {\n");
for (uint64_t children = VDEV_DRAID_MIN_CHILDREN;
children <= VDEV_DRAID_MAX_CHILDREN;
children++) {
uint64_t seed, checksum, nperms, avg_ratio;
nvlist_t *cfg;
char key[8] = {0};
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
snprintf(key, 8, "%llu", (u_longlong_t)children);
error = read_map_key(filename, key, &cfg);
if (error != 0) {
printf("Error read_map_key() failed: %s\n",
strerror(error));
return (1);
}
seed = fnvlist_lookup_uint64(cfg, MAP_SEED);
checksum = fnvlist_lookup_uint64(cfg, MAP_CHECKSUM);
children = fnvlist_lookup_uint64(cfg, MAP_CHILDREN);
nperms = fnvlist_lookup_uint64(cfg, MAP_NPERMS);
avg_ratio = fnvlist_lookup_uint64(cfg, MAP_AVG_RATIO);
printf("\t{ %3llu, %3llu, 0x%016llx, 0x%016llx },\t"
"/* %2.03f */\n", (u_longlong_t)children,
(u_longlong_t)nperms, (u_longlong_t)seed,
(u_longlong_t)checksum, (double)avg_ratio / 1000.0);
nvlist_free(cfg);
}
printf("};\n");
return (0);
}
static int
draid_merge_impl(nvlist_t *allcfgs, const char *srcfilename, int *mergedp)
{
nvlist_t *srccfgs;
nvpair_t *elem = NULL;
int error, merged = 0;
error = read_map(srcfilename, &srccfgs);
if (error != 0)
return (error);
while ((elem = nvlist_next_nvpair(srccfgs, elem)) != NULL) {
uint64_t nv_worst_ratio;
uint64_t allcfg_worst_ratio;
nvlist_t *cfg, *allcfg;
char *key;
switch (nvpair_type(elem)) {
case DATA_TYPE_NVLIST:
(void) nvpair_value_nvlist(elem, &cfg);
key = nvpair_name(elem);
nv_worst_ratio = fnvlist_lookup_uint64(cfg,
MAP_WORST_RATIO);
error = nvlist_lookup_nvlist(allcfgs, key, &allcfg);
if (error == 0) {
allcfg_worst_ratio = fnvlist_lookup_uint64(
allcfg, MAP_WORST_RATIO);
if (nv_worst_ratio < allcfg_worst_ratio) {
fnvlist_remove(allcfgs, key);
error = nvlist_add_nvlist(allcfgs,
key, cfg);
merged++;
}
} else if (error == ENOENT) {
error = nvlist_add_nvlist(allcfgs, key, cfg);
merged++;
} else {
return (error);
}
break;
default:
continue;
}
}
nvlist_free(srccfgs);
*mergedp = merged;
return (0);
}
/*
* Merge the best map for each child count found in the listed files into
* a new file. This allows 'draid generate' to be run in parallel and for
* the results maps to be combined.
*/
static int
draid_merge(int argc, char *argv[])
{
char filename[MAXPATHLEN] = {0};
int c, error, total_merged = 0;
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
nvlist_t *allcfgs;
while ((c = getopt(argc, argv, ":")) != -1) {
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
switch (c) {
case ':':
(void) fprintf(stderr,
"missing argument for '%c' option\n", optopt);
draid_usage();
break;
case '?':
(void) fprintf(stderr, "invalid option '%c'\n",
optopt);
draid_usage();
break;
}
}
if (argc < 4) {
(void) fprintf(stderr,
"A FILE and multiple SRCs must be specified.\n");
return (1);
}
strncpy(filename, argv[optind], MAXPATHLEN - 1);
optind++;
error = read_map(filename, &allcfgs);
if (error == ENOENT) {
allcfgs = fnvlist_alloc();
} else if (error != 0) {
printf("Error read_map(): %s\n", strerror(error));
return (error);
}
while (optind < argc) {
char srcfilename[MAXPATHLEN] = {0};
Distributed Spare (dRAID) Feature This patch adds a new top-level vdev type called dRAID, which stands for Distributed parity RAID. This pool configuration allows all dRAID vdevs to participate when rebuilding to a distributed hot spare device. This can substantially reduce the total time required to restore full parity to pool with a failed device. A dRAID pool can be created using the new top-level `draid` type. Like `raidz`, the desired redundancy is specified after the type: `draid[1,2,3]`. No additional information is required to create the pool and reasonable default values will be chosen based on the number of child vdevs in the dRAID vdev. zpool create <pool> draid[1,2,3] <vdevs...> Unlike raidz, additional optional dRAID configuration values can be provided as part of the draid type as colon separated values. This allows administrators to fully specify a layout for either performance or capacity reasons. The supported options include: zpool create <pool> \ draid[<parity>][:<data>d][:<children>c][:<spares>s] \ <vdevs...> - draid[parity] - Parity level (default 1) - draid[:<data>d] - Data devices per group (default 8) - draid[:<children>c] - Expected number of child vdevs - draid[:<spares>s] - Distributed hot spares (default 0) Abbreviated example `zpool status` output for a 68 disk dRAID pool with two distributed spares using special allocation classes. ``` pool: tank state: ONLINE config: NAME STATE READ WRITE CKSUM slag7 ONLINE 0 0 0 draid2:8d:68c:2s-0 ONLINE 0 0 0 L0 ONLINE 0 0 0 L1 ONLINE 0 0 0 ... U25 ONLINE 0 0 0 U26 ONLINE 0 0 0 spare-53 ONLINE 0 0 0 U27 ONLINE 0 0 0 draid2-0-0 ONLINE 0 0 0 U28 ONLINE 0 0 0 U29 ONLINE 0 0 0 ... U42 ONLINE 0 0 0 U43 ONLINE 0 0 0 special mirror-1 ONLINE 0 0 0 L5 ONLINE 0 0 0 U5 ONLINE 0 0 0 mirror-2 ONLINE 0 0 0 L6 ONLINE 0 0 0 U6 ONLINE 0 0 0 spares draid2-0-0 INUSE currently in use draid2-0-1 AVAIL ``` When adding test coverage for the new dRAID vdev type the following options were added to the ztest command. These options are leverages by zloop.sh to test a wide range of dRAID configurations. -K draid|raidz|random - kind of RAID to test -D <value> - dRAID data drives per group -S <value> - dRAID distributed hot spares -R <value> - RAID parity (raidz or dRAID) The zpool_create, zpool_import, redundancy, replacement and fault test groups have all been updated provide test coverage for the dRAID feature. Co-authored-by: Isaac Huang <he.huang@intel.com> Co-authored-by: Mark Maybee <mmaybee@cray.com> Co-authored-by: Don Brady <don.brady@delphix.com> Co-authored-by: Matthew Ahrens <mahrens@delphix.com> Co-authored-by: Brian Behlendorf <behlendorf1@llnl.gov> Reviewed-by: Mark Maybee <mmaybee@cray.com> Reviewed-by: Matt Ahrens <matt@delphix.com> Reviewed-by: Tony Hutter <hutter2@llnl.gov> Signed-off-by: Brian Behlendorf <behlendorf1@llnl.gov> Closes #10102
2020-11-13 21:51:51 +00:00
int merged = 0;
strncpy(srcfilename, argv[optind], MAXPATHLEN - 1);
error = draid_merge_impl(allcfgs, srcfilename, &merged);
if (error) {
printf("Error draid_merge_impl(): %s\n",
strerror(error));
nvlist_free(allcfgs);
return (1);
}
total_merged += merged;
printf("Merged %d key(s) from '%s' into '%s'\n", merged,
srcfilename, filename);
optind++;
}
if (total_merged > 0)
write_map(filename, allcfgs);
printf("Merged a total of %d key(s) into '%s'\n", total_merged,
filename);
nvlist_free(allcfgs);
return (0);
}
int
main(int argc, char *argv[])
{
if (argc < 2)
draid_usage();
char *subcommand = argv[1];
if (strcmp(subcommand, "generate") == 0) {
return (draid_generate(argc - 1, argv + 1));
} else if (strcmp(subcommand, "verify") == 0) {
return (draid_verify(argc - 1, argv + 1));
} else if (strcmp(subcommand, "dump") == 0) {
return (draid_dump(argc - 1, argv + 1));
} else if (strcmp(subcommand, "table") == 0) {
return (draid_table(argc - 1, argv + 1));
} else if (strcmp(subcommand, "merge") == 0) {
return (draid_merge(argc - 1, argv + 1));
} else {
draid_usage();
}
}