2023-08-24 18:59:03 +00:00
|
|
|
#!/bin/sh
|
2023-08-29 16:12:40 +00:00
|
|
|
# shellcheck disable=SC3014,SC2154,SC2086,SC2034
|
2023-08-24 18:59:03 +00:00
|
|
|
#
|
|
|
|
# Turn off disk's enclosure slot if it becomes FAULTED.
|
|
|
|
#
|
|
|
|
# Bad SCSI disks can often "disappear and reappear" causing all sorts of chaos
|
|
|
|
# as they flip between FAULTED and ONLINE. If
|
2023-12-09 00:32:35 +00:00
|
|
|
# ZED_POWER_OFF_ENCLOSURE_SLOT_ON_FAULT is set in zed.rc, and the disk gets
|
2023-08-24 18:59:03 +00:00
|
|
|
# FAULTED, then power down the slot via sysfs:
|
|
|
|
#
|
|
|
|
# /sys/class/enclosure/<enclosure>/<slot>/power_status
|
|
|
|
#
|
|
|
|
# We assume the user will be responsible for turning the slot back on again.
|
|
|
|
#
|
|
|
|
# Note that this script requires that your enclosure be supported by the
|
|
|
|
# Linux SCSI Enclosure services (SES) driver. The script will do nothing
|
|
|
|
# if you have no enclosure, or if your enclosure isn't supported.
|
|
|
|
#
|
|
|
|
# Exit codes:
|
|
|
|
# 0: slot successfully powered off
|
|
|
|
# 1: enclosure not available
|
2023-12-09 00:32:35 +00:00
|
|
|
# 2: ZED_POWER_OFF_ENCLOSURE_SLOT_ON_FAULT disabled
|
2023-08-24 18:59:03 +00:00
|
|
|
# 3: vdev was not FAULTED
|
|
|
|
# 4: The enclosure sysfs path passed from ZFS does not exist
|
|
|
|
# 5: Enclosure slot didn't actually turn off after we told it to
|
|
|
|
|
|
|
|
[ -f "${ZED_ZEDLET_DIR}/zed.rc" ] && . "${ZED_ZEDLET_DIR}/zed.rc"
|
|
|
|
. "${ZED_ZEDLET_DIR}/zed-functions.sh"
|
|
|
|
|
|
|
|
if [ ! -d /sys/class/enclosure ] ; then
|
|
|
|
# No JBOD enclosure or NVMe slots
|
|
|
|
exit 1
|
|
|
|
fi
|
|
|
|
|
2023-12-09 00:32:35 +00:00
|
|
|
if [ "${ZED_POWER_OFF_ENCLOSURE_SLOT_ON_FAULT}" != "1" ] ; then
|
2023-08-24 18:59:03 +00:00
|
|
|
exit 2
|
|
|
|
fi
|
|
|
|
|
|
|
|
if [ "$ZEVENT_VDEV_STATE_STR" != "FAULTED" ] ; then
|
|
|
|
exit 3
|
|
|
|
fi
|
|
|
|
|
|
|
|
if [ ! -f "$ZEVENT_VDEV_ENC_SYSFS_PATH/power_status" ] ; then
|
|
|
|
exit 4
|
|
|
|
fi
|
|
|
|
|
2023-08-26 18:22:28 +00:00
|
|
|
# Turn off the slot and wait for sysfs to report that the slot is off.
|
|
|
|
# It can take ~400ms on some enclosures and multiple retries may be needed.
|
2023-08-24 18:59:03 +00:00
|
|
|
for i in $(seq 1 20) ; do
|
2023-08-26 18:22:28 +00:00
|
|
|
echo "off" | tee "$ZEVENT_VDEV_ENC_SYSFS_PATH/power_status"
|
|
|
|
|
|
|
|
for j in $(seq 1 5) ; do
|
|
|
|
if [ "$(cat $ZEVENT_VDEV_ENC_SYSFS_PATH/power_status)" == "off" ] ; then
|
|
|
|
break 2
|
|
|
|
fi
|
|
|
|
sleep 0.1
|
|
|
|
done
|
2023-08-24 18:59:03 +00:00
|
|
|
done
|
|
|
|
|
|
|
|
if [ "$(cat $ZEVENT_VDEV_ENC_SYSFS_PATH/power_status)" != "off" ] ; then
|
|
|
|
exit 5
|
|
|
|
fi
|
|
|
|
|
|
|
|
zed_log_msg "powered down slot $ZEVENT_VDEV_ENC_SYSFS_PATH for $ZEVENT_VDEV_PATH"
|